When connecting a Vision800X expansion chassis to a Vision800 machine the H-Link card in the Vision800
mustbeinstalledintothex8slot.TheS-LinkcardintheVision800XshouldbeinstalledinthePICMG1.3
SBC slot.
Connect the H-Link and S-Link cards using the Ex-Cable as shown in the illustrations on the previous page.
Gen-locking Cables on H-Link and S-Link Boards
ConnectorsJ4andJ5areusedforGen-lockingmultiplechassistogether.Thisisusefulwhenusingmultiple
chassisthateachcontainsanumberofDatapathImage4graphicscards.Thegen-lockingchainisused
totietheoutputsofthegraphicscardstogethersothattheyallrendertheiroutputstothescreenatthe
same time. This makes fast moving images appear smoother on the video/data wall and eliminates ‘tear-
ing’artefactsonthedisplay.
Tocreateagen-lockedchainusingtheH-LinkandcorrespondingS-Linkcards,rstlyensurethatthesys-
temispowereddown.Thenconnectthegen-lockoutputoftheclosestImage4graphicscardtoconnector
J4(GENLOCKIN)ontheH-LinkboardusingthecablesuppliedwithyourH-Linkboard,asshowninthe
illustrationbelow.NotethatthiscableislongerthanthecablesuppliedwitheachImage4graphicscard
inordertocovertheextradistancebetweentheImage4andtheH-Linkboard.Thiswillsendthegen-lock
clock over the Ex-Cable to the next downstream chassis.